Designed to work without a PC, the PRO3200 series is a customizable access control that provides real-time processing for connected I/O interfaces.
Product Description:
The PRO3200 professional series family of access control modules is designed for high density installations. Supporting up to 16 readers per enclosure and 32 readers per intelligent controller along with up to 100,000 card capacity provides a combination of small installation footprint and superior cost per door ratio.
Product Features:
- Modular design fits a wide variety of applications
- Up to 9 modules, power-supply and battery can be accommodated by the PRO22ENC1, PRO22ENC2 and PRO22ENC5 (no battery) enclosures
- User programmable relay outputs allow for specific control needs
- User programmable alarm inputs offer flexible system configuration and control
- RS485 communication to all modules
- Analog to digital converter technology provides digital filtering and input conditioning
- Dedicated cabinet tamper and power monitor inputs
- Supports the choice of normally open, normally closed, supervised, and non-supervised circuits
- Supports a wide range of reader technologies including Wiegand, magnetic stripe, proximity, and keypad
- System off-line modes customizable per reader include facility code access, locked (no access),
- Supports multiple reader and card formats for maximum flexibility and security options
- Operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN and PIN only
- Communication to the host is via either 10/100 Ethernet or RS-232(both are standard)
- Alarm circuit type – normally open, normally closed, non-supervised, supervised (with correct EOL). Meets requirements for UL294 and CUL
- Any combination of 16 I/0 or readers modules may be connected to the PRO32IC RS485 ports. 4,000 ft (1,250 m) total bus length per port
- Supports over 50,000 cards and 50,000 transactions
Technical Specification (Set 1)
MODELS | ||
PRO3200 Series Single Reader Module (PRO22R1) | PRO3200 Series Dual Reader Module (PRO32R2) | |
Module Specifications | ||
Port | 1 reader port – 12 VDC at 50 mA, clock / data or data0 / data1 | |
Keypad | Keypad multiplexed with card data | |
Wire Support | Two-wire or one-wire bi-color LED support | |
Buzzer Support | Buzzer support only with one-wire LED control | |
Alarm Inputs | 2 supervised, general purpose alarm inputs with programmable circuit type | 8 supervised, general purpose alarm inputs withprogrammable circuit type (only 6 supervisedinputs available when using PRO22ENC1,PRO22ENC2 and PRO22ENC5 enclosures) |
Alarm Inputs | 1 dedicated alarm input for tamper detection | 2 dedicated alarm inputs for tamper detection andpower loss |
Output Relays | 1 general purpose output relay, form C, 5 A 28 VDC | 2 general purpose output relay, form C, 5 A 28 VDC |
Output Relays | 1 general purpose output relay, form C, 1 A 28 VDC | 4 general purpose output relay, form C, 2 A 28VDC(only 2 output relays available when usingPRO22ENC1, PRO22ENC2 and PRO22ENC5enclosures) |
Mounting | Designed to be tile-mounted using thePRO22ENC4 enclosure | N/A |
Alarm Input Properties | ||
Inputs | Inputs may be assigned to door related functions or general purpose I/O | |
Circuit Type | Circuit type – normally open, normally closed, non-supervised, supervised (with standard 1K or custom end-of-line resistance 200-10K) | |
Line Conditioning | Line conditioning – programmable sensitivity and hold time | |
Output Control Properties | ||
Outputs | Outputs may be assigned to door related functions or general purpose I/O | |
Relay Rating | The 5 A relay(s) are rated to handle the inductive loads of door locking devices | |
Configurable | Configurable as standard (energize to activate) or fail-safe (de-energize to activate) | |
Pulse Time | 1-32,400 seconds, 1-255 for door relays | |
RS485 Port | RS485 port, 4,000 ft (1,250m) total bus length | |
Standard Speed | 38.4 Kbps |
Technical Specification (Set 2)
MODELS | ||
PRO3200 Series Sixteen Relay Output Module(PRO32OUT) | PRO3200 Series Sixteen Alarm Input Module(PRO32IN) | |
Module Specifications | ||
Alarm Inputs | 2 dedicated alarm inputs for tamper detection and power loss (tile-mounted only) | |
Alarm Inputs | N/A | 16 general purpose inputs with programmablecircuit type |
Output Relays | 12 general purpose output relays, form C, 2 A 30VDC(16 are available when using PRO22ENC3 tile-mounted enclosure) | 2 general purpose, form C, 2 A 30 VDC relays(only one available when using PRO22ENC1,PRO22ENC2 and PRO22ENC5) |
Output Control Properties | ||
Outputs | All 16-relay outputs in the tile-mount configuration(12″ rack-mount) are available for generalpurpose I/O | Both relay outputs are available for generalpurpose I/O |
Dry Circuit Logic | The 2 A relays are rated to handle dry circuit logic | Both relay outputs are rated to handle dry circuitlogic |
Pulse Time | 1-32,400 seconds | |
Configurable | Configurable as standard (energize to activate) orfail-safe (de-energize to activate) | N/A |
Alarm Input Properties | ||
Inputs | N/A | All 16 inputs may be assigned to door relatedfunctions or general purpose I/O |
Circuit Type | N/A | Circuit type – normally open, normally closed,non-supervised, supervised (with correct EOL) |
Line Conditioning | N/A | Line conditioning – programmable sensitivity and hold time |
Communication Features | ||
Measurements | RS485 port, 4,000 ft (1,250m) total bus length per port | |
Speed | 38.4 Kbps |